BEKO METPOINT® OCV Hydrocarbon Monitoring
FOR > 3″ PIPES W/ PROBE & COMMUNICATION CABLE
Hydrocarbons are perhaps the most debilitating by-product of compressed air use; both to production processes and human beings alike. Their presence in a compressed air stream can cost millions of dollars or more importantly a life.
BEKO offers devices at clear-cut investment costs that will monitor hydrocarbons found in compressed air. They enable a significant increase in safety and peace of mind, as well as process control and the corresponding reduction in operating costs. Benefits to which a value cannot be placed.
INCLUDES
- Inline measurement of all C6 hydrocarbons and above
- Globally unique and cutting edge technology
- Reliable, simple and easy to use and understand
- Data log is standard equipment
MODEL SPECIFICATIONS
If you have questions or would like to order over the phone, contact our customer service toll-free: 866-650-1937.
Model Number | Pipe Lenght | Data Log | Probe | Communication Cable | Optional Output | Inline Measurement* |
1278026 | > 3″ Custom | included | included | included | - | all C6 hydrocarbons and above |
* Indentifiable Substances: Polyalphaolefins, aliphatic hydrocarbons (hexane, heptane), hydrocarbons, functional hydrocarbons (alcohols, ketones, amines, halogenated hydrocarbons), and aromatics
24 / 7 PROCESS RELIABILITY
Exclusive inline measuring technology that is unique in the world (meets ISO standards)
CONTINUOUS REFERENCE AIR SAMPLE
The reference air generator takes real time, self-adjusting reference air samples automatically
ON-SITE CALIBRATION
Integrated probe port allows for easy, simplified calibrations without downtime or added costs
NETWORK COMPATIBLE
Includes data logger and full control whether on-site or from remote location
TOUCHSCREEN DISPLAY
Complete diagnostic, multi-function display with all parameters including alarm function
DIMENSIONS & SPECIFICATIONS
- Dimensions: 19.2 x 6.7 x 4.7 in (W x H x D)
- Power Supply: 110 VAC 60 Hz
- Medium: Compressed Air or Nitrogen
- Indentifiable Substances: Polyalphaolefins, aliphatic hydrocarbons (hexane, heptane), hydrocarbons, functional hydrocarbons (alcohols, ketones, amines, halogenated hydrocarbons), and aromatics
- Operating Temperature: +32 to +131 °F
- Operating Over-pressure: 44 to 232 psig
- Measuring Gas Humidity: ≤ 40% relative humidity
- Measured Increments: mg/m3 (per ISO 1217 standard)
- Measuring Range: ≤ 0.001 – 5,000 mg/m3 residual oil vapor content (per ISO 8573-1 standard)
- Connection: 3/8″ internal thread
- Installation Requirements: Vertically in a rising main with an oil and grease free measuring section
- Working Temperature: +32 to +122 ºF
- Dimensions: 9.1 x 7.9 x 4.7 in (W x H x D)
- Outputs: Potential-free change-over contact 230 VAC / 5A or 30 VAC / 2A – Ethernet Interface 4 to 20 mA (optional)
- Power Supply: 85 – 264 VAC / 47 – 63 Hz
- Installed Memory: 2 GB Internal Memory with Data Log
CERTIFIED
The measureing system METPOINT OCV meets the requirements for the measurement of vapour oil and hydrocarbon in accordance with ISO 8373-1 Class 1, 2, 3, and 4.
ACCESSORIES & SERVICES
Contact us for more information on BEKO METPOINT© OCV replacement parts and services toll-free: 866-650-1937 or order online now.
Software Package: communication cable and data logging software
Replacement Probe: for 3/4″ – 1-1/2″ pipes
Replacement Probe: for 2″ – 3″ pipes
Replacement Probe: for custom lenght pipes
Calibration Service: annual maintenance service
Category