BEKO METPOINT® OCV Hydrocarbon Detector
FOR 3/4″ TO 3″ PIPES AND CUSTOM LENGTH
Hydrocarbons are perhaps the most debilitating by-product of compressed air use; both to production processes and human beings alike. Their presence in a compressed air stream can cost millions of dollars or more importantly a life.
BEKO offers devices at clear-cut investment costs that will monitor hydrocarbons found in compressed air. They enable a significant increase in safety and peace of mind, as well as process control and the corresponding reduction in operating costs. Benefits to which a value cannot be placed. Learn more about BEKO hydrocarbon leak detector and how it can help your system.
INCLUDES
- • Inline measurement of all C6 hydrocarbons and above
- • Globally unique and cutting edge technology
- • Reliable, simple and easy to use and understand
- • Data log is standard equipment
MODEL SPECIFICATION
Select a model below to see pricing, order, or more information on the BEKO METPOINT OCV Hydrocarbon Monitoring Device. If you have questions or would like to order over the phone, contact our customer service toll-free: 866-650-1937.
Model Number | Pipe Length | Data Log | Probe | Communication Cable | Optional Output | Inline Measurement* |
4013408 | 3/4″ – 1-1/2″ | included | included | included | - | all C6 hydrocarbons and above |
4013710 | 3/4″ – 1-1/2″ | included | included | included | 4 – 20 mA output | all C6 hydrocarbons and above |
4013409 | 2″ – 3″ | included | included | included | - | all C6 hydrocarbons and above |
4013711 | 2″ – 3″ | included | included | included | 4 – 20 mA output | all C6 hydrocarbons and above |
4013410 | > 3″ Custom | included | included | included | - | all C6 hydrocarbons and above |
4013712 | > 3″ Custom | included | included | included | 4 – 20 mA output | all C6 hydrocarbons and above |
* Indentifiable Substances: Polyalphaolefins, aliphatic hydrocarbons (hexane, heptane), hydrocarbons, functional hydrocarbons (alcohols, ketones, amines, halogenated hydrocarbons), and aromatics
4013408
24 / 7 PROCESS RELIABILITY
Exclusive inline measuring technology that is unique in the world (meets ISO standards)
CONTINUOUS REFERENCE AIR SAMPLE
The reference air generator takes real time, self-adjusting reference air samples automatically
ON-SITE CALIBRATION
Integrated probe port allows for easy, simplified calibrations without downtime or added costs
NETWORK COMPATIBLE
Includes data logger and full control whether on-site or from remote location
TOUCHSCREEN DISPLAY
Complete diagnostic, multi-function display with all parameters including alarm function
DIMENSIONS & SPECIFICATIONS
- Dimensions: 19.2 x 6.7 x 4.7 in (W x H x D)
- Power Supply: 110 VAC 60 Hz
- Medium: Compressed Air or Nitrogen
- Indentifiable Substances: Polyalphaolefins, aliphatic hydrocarbons (hexane, heptane), hydrocarbons, functional hydrocarbons (alcohols, ketones, amines, halogenated hydrocarbons), and aromatics
- Operating Temperature: +32 to +131 °F
- Operating Over-pressure: 44 to 232 psig
- Measuring Gas Humidity: ≤ 40% relative humidity
- Measured Increments: mg/m3 (per ISO 1217 standard)
- Measuring Range: ≤ 0.001 – 5,000 mg/m3 residual oil vapor content (per ISO 8573-1 standard)
- Connection: 3/8″ internal thread
- Installation Requirements: Vertically in a rising main with an oil and grease free measuring section
- Working Temperature: +32 to +122 ºF
- Dimensions: 9.1 x 7.9 x 4.7 in (W x H x D)
- Outputs: Potential-free change-over contact 230 VAC / 5A or 30 VAC / 2A – Ethernet Interface 4 to 20 mA (optional)
- Power Supply: 85 – 264 VAC / 47 – 63 Hz
- Installed Memory: 2 GB Internal Memory with Data Log
CERTIFIED
The measureing system METPOINT OCV meets the requirements for the measurement of vapour oil and hydrocarbon in accordance with ISO 8373-1 Class 1, 2, 3, and 4.
ACCESSORIES & SERVICES
Contact us for more information on BEKO METPOINT© OCV replacement parts and services toll-free: 866-650-1937 or order online now.
Software Package: communication cable and data logging software
Replacement Probe: for 3/4″ – 1-1/2″ pipes
Replacement Probe: for 2″ – 3″ pipes
Replacement Probe: for custom lenght pipes
Calibration Service: annual maintenance service
Category